LOOP DETECTORS
INSTALLATION
STEP 1. Using Removable Connector, Connect wire (twisted pair) from each in-
ground loop as indicated.
STEP 2. Plug in Eagle Loop Detector to
Corresponding In-ground Loop as indicated
(USE ONLY EAGLE BRAND PLUG-IN
LOOP DETECTORS)
S
TEP 3. Eagle Loop
Detectors automatically ad-
just for proper
sensitivity.
Note: Eagle Brand Plug-in Loop De-
tectors are designed as “fail-Safe.”
Wire (Twisted Pair) From In-ground Loop Connects to Proper LOOP WIRE INPUT
1 2 3 4
Eagle Loop Detectors Plug into Corresponding LOOP DETECTORS CONNECTIONS
1 2 3
LED INDICATORS
Green LED (Upper LED)
Steady On = Power
Fast Blink = Shorted Loop Wire
Slow Blink = Open Loop
Red LED (Lower LED)
On = Vehicle Detection